听力与言语-语言病理学

行为科学

医学伦理学

你正在浏览JOURNAL OF ORTHOPAEDIC TRAUMA期刊下所有文献
  • Trauma program development.

    abstract::The development of a strong trauma program is clearly one of the most important facets of successful business development. Several recent publications have demonstrated that well run trauma services can generate significant profits for both the hospital and the surgeons involved. There are many aspects to this task th...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000142

    authors: Althausen PL

    更新日期:2014-07-01 00:00:00

  • Treatment of Gartland type III pediatric supracondylar humerus fractures with the Kapandji technique in the prone position.

    abstract:OBJECTIVE:The purpose of this study was to report the efficacy of the Kapandji technique performed in the prone position for humeral supracondylar fractures in children. DESIGN:Retrospective. SETTING:Level I trauma center. PATIENTS/PARTICIPANTS:We retrospectively reviewed 34 children with Gartland type III supracond...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000015

    authors: Kao HK,Yang WE,Li WC,Chang CH

    更新日期:2014-06-01 00:00:00

  • Metaphyseal screw augmentation of the LISS-PLT plate with polymethylmethacrylate improves angular stability in osteoporotic proximal third tibial fractures: a biomechanical study in human cadaveric tibiae.

    abstract:OBJECTIVES:The incidence of osteoporotic proximal tibial fractures has increased during the last 2 decades. A promising approach in osteoporotic fracture fixation is polymethylmethacrylate-based cement augmentation of implants to gain better implant purchase in the bone. This study investigates the biomechanical benefi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000004

    authors: Goetzen M,Nicolino T,Hofmann-Fliri L,Blauth M,Windolf M

    更新日期:2014-05-01 00:00:00

  • Operating room efficiency: benefits of an orthopaedic traumatologist at a level II trauma center.

    abstract:OBJECTIVES:Fellowship-trained orthopaedic traumatologists are presumably taught skill sets leading to "best practice" outcomes and more efficient use of hospital resources. This should result in more favorable economic opportunities when compared with general orthopaedic surgeons (GOSs) providing similar clinical servi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a59d6b

    authors: Althausen PL,Kauk JR,Shannon S,Lu M,O'Mara TJ,Bray TJ

    更新日期:2014-05-01 00:00:00

  • Common factors and outcome in late upper extremity amputations after military injury.

    abstract:OBJECTIVES:Much attention has been given to lower extremity amputations that occur more than 90 days after injury, but little focus has been given to analogous upper extremity amputations. The purpose of this study was to determine the reason(s) for desired amputation and the common complications after amputation for t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a665f5

    authors: Krueger CA,Wenke JC,Cho MS,Hsu JR

    更新日期:2014-04-01 00:00:00

  • Can the "turn-of-the-nut" method improve cortical screw fixation?

    abstract:OBJECTIVES:To determine the angular rotation that maximizes screw tension without sacrificing screw pullout force yet minimizing loss of screw purchase. METHODS:Three pairs of human humeri in each of the 3 groups (osteopenic, osteoporotic, and normal) underwent screw tension and pullout protocols. For screw tension, 3...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000435631.71393.60

    authors: Thakkar SC,Langdale ER,Mears SC,Belkoff SM

    更新日期:2014-04-01 00:00:00

  • Do locking screws work in plates bent at holes?

    abstract:OBJECTIVES:To assess whether plate bending at a hole significantly changes the biomechanical properties of a locked screw. METHODS:Coronal plane bends of 5-, 15-, or 45-degree angles were placed in 3.5-mm locking compression plates with the apex at a locking hole. An additional 45-degree angle test group was created i...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a73a77

    authors: Boulton CL,Kim H,Shah SB,Ryan SP,Metzger TA,Hsieh AH,O'Toole RV

    更新日期:2014-04-01 00:00:00

  • The effects of varus or valgus malalignment of proximal ulnar fractures on forearm rotation.

    abstract:INTRODUCTION:Proximal ulna fractures can cause a significant loss of forearm rotation, elbow stiffness, and disability. The objective of this study was to quantify the loss of forearm rotation after simulated varus and valgus malunions of the proximal ulna. METHODS:Eight cadaveric upper extremities were used to quanti...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31829f5ebc

    authors: Snow BJ,Javidan P,Itamura JM,Lee TQ

    更新日期:2014-03-01 00:00:00

  • Long-term outcome after operative treatment of traumatic patellar dislocation in adolescents.

    abstract:OBJECTIVES:Retrospective evaluation of the long-term outcomes after surgical treatment of traumatic patellar dislocations in adolescents and identification of possible predictive factors of poor outcomes. DESIGN:Retrospective clinical study. SETTING:University Clinic, Level I Trauma Center. PATIENTS:All 33 adolescen...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318299cb50

    authors: Hartmann F,Dietz SO,Rommens PM,Gercek E

    更新日期:2014-03-01 00:00:00

  • Intramedullary allograft fibula as a reduction and fixation tool for treatment of complex proximal humerus fractures with diaphyseal extension.

    abstract:SUMMARY:In this study, we present a novel technique for reduction and fixation of complex, unstable proximal humerus fractures with diaphyseal extension with the assistance of fibula allograft. We treated 14 patients using this technique since 2009 and found that it improves the reduction and enhances fixation while ma...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31829a346d

    authors: Berkes MB,Little MT,Lazaro LE,Cymerman RM,Pardee NC,Helfet DL,Dines JS,Lorich DG

    更新日期:2014-03-01 00:00:00

  • Mechanical effects of off-axis insertion of locking screws: should we do it?

    abstract:OBJECTIVES:The purposes of this study were to evaluate the cantilevered bending strength and failure modes of locking screws inserted at various angles in a plate with fully circumferential threaded holes. As an additional measure, the amount of screw head prominence at these angles was also assessed. METHODS:Standard...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000066

    authors: Cartner JL,Petteys T,Tornetta P 3rd

    更新日期:2014-01-01 00:00:00

  • Evidence gaps in the global decade of road traffic safety.

    abstract::Road traffic accidents are a leading cause of global mortality. In March 2010, the United Nations General Assembly and the World Health Organization (WHO) officially proclaimed 2011-2020 as the "Decade of Action for Road Safety." Researchers must focus on vulnerable road users and low- and middle-income countries (LMI...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000103

    authors: Evaniew N,Godin K,Schemitsch EH,Bhandari M

    更新日期:2014-01-01 00:00:00

  • Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery.

    abstract::The surgical treatment of pelvic and acetabular fractures can be technically challenging. Various techniques are available for the reconstruction of pelvic and acetabular fractures. Less invasive percutaneous fracture stabilization techniques, with closed reduction or limited open reduction, have been developed and ar...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e318288c0c3

    authors: Yi C,Burns S,Hak DJ

    更新日期:2014-01-01 00:00:00

  • Medial elbow exposure for coronoid fractures: FCU-split versus over-the-top.

    abstract:OBJECTIVE:The optimal exposure interval for anteromedial coronoid fractures is unknown. The purpose of this study was to quantitatively compare the osseous and ligamentous exposure of the medial elbow using the flexor carpi ulnaris (FCU)-Splitting and Hotchkiss Over-the-Top approaches. METHODS:Forty surgical approache...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828ba91c

    authors: Huh J,Krueger CA,Medvecky MJ,Hsu JR,Skeletal Trauma Research Consortium.

    更新日期:2013-12-01 00:00:00

  • A method for detection of lateral malleolar malrotation using conventional fluoroscopy.

    abstract::Recent studies on ankle syndesmosis injuries have shown that a significant amount of rotational malediction of the distal fibula are missed and may lead to poor functional outcome. A new set of radiographic criteria were developed to help detect distal fibula internal and external rotation using conventional fluorosco...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828f89a9

    authors: Marmor M,Kandemir U,Matityahu A,Jergesen H,McClellan T,Morshed S

    更新日期:2013-12-01 00:00:00

  • CT scan assessment of the syndesmosis: a new reproducible method.

    abstract:OBJECTIVES:Anatomic reduction of the fibula with regard to the tibia is the goal when treating syndesmotic injuries. No objective method exists to describe the distal tibiofibular relationship. The primary and secondary objectives of this study was to describe and validate radiologic measurements of the syndesmosis and...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318284785a

    authors: Nault ML,Hébert-Davies J,Laflamme GY,Leduc S

    更新日期:2013-11-01 00:00:00

  • Kirschner wire bending.

    abstract::Although Kirschner wires are useful implants in many situations, migration of the wire and irritation of the surrounding soft tissues are common complications. Seven steps are described herein, which result in a Kirschner wire that is bent 180° angle, providing a smooth anchor into bone. Use of this technique produces...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318290f818

    authors: Firoozabadi R,Kramer PA,Benirschke SK

    更新日期:2013-11-01 00:00:00

  • Barefoot stubbing injuries to the great toe in children: a new classification by injury mechanism.

    abstract:OBJECTIVE:This study was conducted to categorize barefoot stubbing injuries to the great toe in children by injury mechanism to differentiate benign stubbing injuries from more complex injuries necessitating surgery. DESIGN:Prospective clinical series of consecutively treated patients. SETTING:Tertiary university hos...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828e5d39

    authors: Park DY,Han KJ,Han SH,Cho JH

    更新日期:2013-11-01 00:00:00

  • Getting organized in your job.

    abstract::The benefits of being organized when starting one's career are countless and worth the time and effort in developing an effective and efficient practice. Established protocols, good habits, and methodical communication that include all members of the team will help create a system that keeps all components of one's pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a52344

    authors: Siegel J

    更新日期:2013-10-01 00:00:00

  • Computed tomography scan to detect traumatic arthrotomies and identify periarticular wounds not requiring surgical intervention: an improvement over the saline load test.

    abstract:OBJECTIVE:To report our experience with computed tomography (CT) scans to detect traumatic arthrotomies of the knee (TAK) joint based on the presence of intra-articular air. DESIGN:Retrospective review. SETTING:Level I trauma center. PATIENTS:Sixty-two consecutive patients (63 knees) underwent a CT scan of the knee ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828219bc

    authors: Konda SR,Davidovitch RI,Egol KA

    更新日期:2013-09-01 00:00:00

  • Percutaneous autologous bone marrow injection in the treatment of distal meta-diaphyseal tibial nonunions and delayed unions.

    abstract:OBJECTIVE:To report the outcomes of percutaneous autologous bone marrow injection for nonunion or delayed union of the distal tibial metaphysis in patients with prior plating. DESIGN:Consecutive case series. SETTING:Tertiary center. PATIENTS:Eleven consecutive patients (aged 24-51 years) were referred to us with a n...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31828bf077

    authors: Braly HL,O'Connor DP,Brinker MR

    更新日期:2013-09-01 00:00:00

  • In vitro toxicity and activity of Dakin's solution, mafenide acetate, and amphotericin B on filamentous fungi and human cells.

    abstract:OBJECTIVES:Posttraumatic invasive fungal infections threaten critically injured combat-related injuries and require a combination of extensive surgery and systemic antifungal therapy, along with topical antimicrobials used adjunctively to control the infection. We evaluated the in vitro activity of topical agents in va...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182830bf9

    authors: Barsoumian A,Sanchez CJ,Mende K,Tully CC,Beckius ML,Akers KS,Wenke JC,Murray CK

    更新日期:2013-08-01 00:00:00

  • Avoiding rotational mismatch of locking distal tibia plates depends on proper plate position.

    abstract:OBJECTIVES:The purpose of this study was to evaluate the most appropriate positioning of anatomical locking plates on the distal tibia. METHODS:We positioned 4 types of locking plates (3 straight and 1 bayonet) at anterior, middle, and posterior positions on the medial malleolus on both lower limbs of 15 cadavers. We ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31827cd67d

    authors: Song HK,Noh JW,Lee JH,Yang KH

    更新日期:2013-07-01 00:00:00

  • Anteroinferior 2.7-mm versus 3.5-mm plating for AO/OTA type B clavicle fractures: a comparative cohort clinical outcomes study.

    abstract:OBJECTIVES:To compare the Disability of the Arm, Shoulder, and Hand (DASH) and Constant scores, time to union, rate of union, patient cosmetic satisfaction rate, and the need for secondary procedures between 2.7- and 3.5-mm anteroinferior plating for Arbeitsgemeinschaft für Osteosynthesefragen (AO)/Orthopaedic Trauma A...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182693f32

    authors: Galdi B,Yoon RS,Choung EW,Reilly MC,Sirkin M,Smith WR,Liporace FA

    更新日期:2013-03-01 00:00:00

  • The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures.

    abstract:OBJECTIVES:The purpose of this study was to evaluate forearm rotation after volar plating of the distal radius fractures with and without pronator quadratus repair. DESIGN:This was an institutional review board-approved retrospective review of prospectively collected data. SETTING:The study was conducted at an Academ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182539333

    authors: Hershman SH,Immerman I,Bechtel C,Lekic N,Paksima N,Egol KA

    更新日期:2013-03-01 00:00:00

  • A new ankle spanning fixator construct for distal tibia fractures: optimizing visualization, minimizing pin problems, and protecting the heel.

    abstract::Pilon and ankle fractures and ligamentous injuries about the ankle often require external fixation to allow for soft tissue stabilization before definitive surgery. Often used external fixator constructs can cause obscuring of the site of injury on radiographs, pin tract infections, loosening of calcaenal pin fixation...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182604639

    authors: Ziran BH,Morrison T,Little J,Hileman B

    更新日期:2013-02-01 00:00:00

  • Predrilling does not improve the pullout strength of external fixator pins: a biomechanical study.

    abstract:OBJECTIVES:External fixator pins are thought to have improved pullout strength if inserted into both cortices and if pilot holes are drilled. We tested these hypotheses and investigated effects of osteoporosis and pin location on pin pullout strength. METHODS:Self-drilling external fixator pins were inserted using 4 t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182511ed7

    authors: Oliphant BW,Kim H,Osgood GM,Golden RD,Hawks MA,Hsieh AH,OʼToole RV

    更新日期:2013-02-01 00:00:00

  • Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures.

    abstract:OBJECTIVES:The aim of this study was analyze modes of mechanical failure in a consecutive cohort of patients and establish possible risk factors. DESIGN:This was a retrospective cohort study. SETTING:The study was conducted at an academic level-1 trauma center. PATIENTS:Twenty-nine patients (mean age 56 years, range...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318251930d

    authors: Streubel PN,Moustoukas MJ,Obremskey WT

    更新日期:2013-01-01 00:00:00

  • Lengthening over a retrograde nail using 3 Schanz pins.

    abstract::The technique of lengthening over an antegrade nail is used widely for distraction osteogenesis of the femur. Most reported complications of this technique are related to Schanz pins. We hypothesized that reducing the number of Schanz pins would enable successful distraction with fewer complications. To this purpose, ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31824a3e66

    authors: Kucukkaya M,Karakoyun O,Kuzgun U

    更新日期:2013-01-01 00:00:00

  • Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.

    abstract:OBJECTIVE:The purpose of this study was to determine if proximity of cannulated lag screws to the articular surface of the patella combined with the tension band technique affects resistance to fracture gap opening, and if an alternative locking nut and bolt device without a tension band behaves in a biomechanically si...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31826f5985

    authors: Domby B,Henderson E,Nayak A,Erdoğan M,Gutierrez S,Santoni BG,Sagi HC

    更新日期:2012-12-01 00:00:00

  • Physiological challenges of bone repair.

    abstract::Bone healing after fracture occurs in a well-organized manner and involves a multitude of cell types, inflammatory cytokines, growth factors, prostaglandins, and certain vitamins. Some of the means by which alterations in these essential components affect bone repair are understood, whereas others still need to be del...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e318274da8b

    authors: Borrelli J Jr,Pape C,Hak D,Hsu J,Lin S,Giannoudis P,Lane J

    更新日期:2012-12-01 00:00:00

  • Inflammatory cytokine and chemokine expression is associated with heterotopic ossification in high-energy penetrating war injuries.

    abstract:OBJECTIVE:Heterotopic ossification (HO) develops frequently after modern high-energy penetrating war injuries. The purpose of this prospective study was to identify and characterize the unique cytokine and chemokine profile associated with the development of HO as it pertained to the systemic inflammatory response afte...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31825d60a5

    authors: Evans KN,Forsberg JA,Potter BK,Hawksworth JS,Brown TS,Andersen R,Dunne JR,Tadaki D,Elster EA

    更新日期:2012-11-01 00:00:00

  • Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.

    abstract:OBJECTIVES:To introduce a modified operative technique for minimally invasive plate osteosynthesis (MIPO) for acute displaced humeral shaft fractures and to evaluate the clinical and radiological outcomes. DESIGN:: Prospective clinical series study. SETTING:University hospital. PATIENTS:Twenty-one patients with acut...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318254895f

    authors: Shin SJ,Sohn HS,Do NH

    更新日期:2012-10-01 00:00:00

  • The effects of clopidogrel (Plavix) and other oral anticoagulants on early hip fracture surgery.

    abstract:OBJECTIVE:Risk for bleeding complications during and after early hip fracture surgery for patients taking clopidogrel and other anticoagulants have not been defined. The purpose of this study is to assess the perioperative bleeding risks and clinical outcome after early hip fracture surgery performed on patients taking...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318240d70f

    authors: Collinge CA,Kelly KC,Little B,Weaver T,Schuster RD

    更新日期:2012-10-01 00:00:00

  • Efficacy of popliteal block in postoperative pain control after ankle fracture fixation: a prospective randomized study.

    abstract:OBJECTIVES:To compare postoperative pain control in patients treated surgically for ankle fractures who receive popliteal blocks with those who received general anesthesia alone. DESIGN:Institutional Review Board approved prospective randomized study. SETTING:Metropolitan tertiary-care referral center. PATIENTS:All ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0b013e3182638b25

    authors: Goldstein RY,Montero N,Jain SK,Egol KA,Tejwani NC

    更新日期:2012-10-01 00:00:00

  • Negative pressure wound therapy reduces deep infection rate in open tibial fractures.

    abstract:OBJECTIVES:To evaluate the effect of negative pressure wound therapy (NPWT) on deep infection rate in open tibial fractures. DESIGN:Retrospective cohort study. Data was collected from medical records and radiographs. SETTING:Two level-1 trauma centers. PATIENTS/PARTICIPANTS:Patients who sustained an open tibial frac...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31824133e3

    authors: Blum ML,Esser M,Richardson M,Paul E,Rosenfeldt FL

    更新日期:2012-09-01 00:00:00

  • The protective effect of locking screw placement on nonlocking screw extraction torque in an osteoporotic supracondylar femur fracture model.

    abstract:OBJECTIVE:To examine the impact of number and position of locking screws in the diaphyseal portion of an osteoporotic distal femoral fracture model with hybrid fixation. METHODS:Four groups containing 5 osteoporotic bone models were used with varying combinations of diaphyseal screw fixation: 4 nonlocking screws (cont...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318238c086

    authors: Dalstrom DJ,Nelles DB,Patel V,Goswami T,Markert RJ,Prayson MJ

    更新日期:2012-09-01 00:00:00

  • Regional anesthesia improves outcome after distal radius fracture fixation over general anesthesia.

    abstract:OBJECTIVE:To compare the efficacy of anesthetic type on clinical outcomes after operative treatment of distal radius fractures. DESIGN:Retrospective review of prospectively collected data. SETTING:Academic medical center. PATIENTS:One hundred eighty-seven patients with a distal radius fracture (OTA type 23) were ide...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318238becb

    authors: Egol KA,Soojian MG,Walsh M,Katz J,Rosenberg AD,Paksima N

    更新日期:2012-09-01 00:00:00

  • The effects of locked and unlocked neutralization plates on load bearing of fractures fixed with a lag screw.

    abstract:OBJECTIVES:Because locked plates as a neutralization device for lag screw fracture fixation have different biomechanics than that of unlocked plates, we investigated how this would affect lag screw load at the fracture site. The purpose of this study was to assess the load at a fracture site compressed with a lag screw...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31823b3dd1

    authors: Takemoto RC,Sugi MT,Kummer F,Koval KJ,Egol KA

    更新日期:2012-09-01 00:00:00

  • The realities of relationship failure.

    abstract::Young surgeons and their spouses experience a myriad of stresses in the first few years of practice. Issues related to job search, moving to a new community, learning one's craft, time management, changes to spouse's career, child rearing, and the ever blurring line between work time and free time may all contribute t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182641fd8

    authors: Dunbar RP Jr

    更新日期:2012-09-01 00:00:00

462 条记录 5/12 页 « 12345678...1112 »